Suction of 80% of the discharge air! OKE-MB01FJ suction measurement.
Measurement of self-priming capacity of OKE-MB01FJ (7L/min)
We will measure the self-priming volume of standard and semi-standard nozzles. Measurements will be taken in increments from 0.00 to 0.01 MPa. The experimental results yielded unexpectedly very interesting findings, revealing the existence of water pressure at which the self-priming volume becomes discontinuous. The experimental conditions were set with a water heater temperature of 43°C, utilizing tap water pressure. The self-priming inlet was fully opened using a throttle valve. A 6mm outer diameter tube of 2 meters was used, with a check valve that has a cracking pressure close to 0 in between. The measuring device for the self-priming volume was the Horiba Manufacturing Corporation Estec Digital Flow Meter SEF-51. The nozzle used was OKE-MB01FJ with a discharge capacity of 7L/min (at water pressure of 0.15 MPa). For more details, please contact us or refer to the catalog.
- Company:OKエンジニアリング